AC charging. Everyday destinations.
A catalogue family for home, workplace and destination charging discussions.
PEVC2107EExplore this family →
RedRooEnergyHelping Australia Access Renewable EnergyPILOT / SMART ENERGY & EV CHARGING
Smart energy and EV charging for Australian project conversations.
Explore EV charging →PILOT IN AUSTRALIA
Explore your next energy project with Pilot Technology Australia Pty Ltd. Bring your requirements to the local team in Mulgrave, Victoria.
Discover the company, explore charging and integrated energy solutions, and connect with its Australian business team.

Discover the company behind the charging catalogue.
Explore our company →
Browse eight AC, DC and split-system catalogue families.
Explore EV chargers →
Explore metering, storage, solar integration and charging for your site.
Explore Australian solution pathways →Explore selected families from the supplier catalogue.
View all eight product families →A catalogue family for home, workplace and destination charging discussions.
PEVC2107EExplore this family →
Explore a compact DC family for commercial charging applications.
PEVC3401EExplore this family →
Review integrated DC charging options around the requirements of your site.
PEVC3107EExplore this family →
Explore the split-system family and its cabinet and dispenser arrangements.
PEVC3302EExplore this family →
Manufacturer artwork and catalogue family previews. Confirm the exact Australian model, connector, compliance, availability and included equipment before selection.
Bring your model, site and application questions together.
ABOUT PILOT / AUSTRALIA
From understanding electricity use to planning EV charging and energy storage, PILOT brings a connected perspective to the way Australian businesses approach energy.

EXPERIENCE BEHIND THE TECHNOLOGY
Established in 2000, Zhuhai Pilot Technology Co., Ltd. develops energy metering, battery storage and EV charging technologies. Its manufacturer profile describes research, development and production capabilities supporting these areas.
For Australian retailers, installers, builders and commercial buyers, this RRE storefront brings the supplied charger families and their original catalogue documents together in one place.
Pilot Technology Australia Pty Ltd provides the Australian business contact for your enquiry. Discuss the site, intended application and preferred equipment before moving towards a project proposal.
Whether you are considering a workplace charger or exploring a broader energy system, begin with a clear brief and model-specific information.
Speak with the Australian team →
FROM SOURCE TO SELECTION
Review the manufacturer’s product information, compare the supplied specifications and keep the exact configuration in view. Australian certification, installation and service arrangements must be confirmed for the equipment you select.
Read catalogue documents →Overseas manufacturing image; not an Australian installation.
PILOT IN AUSTRALIA
Explore your next energy project with Pilot Technology Australia Pty Ltd. Bring your requirements to the local team in Mulgrave, Victoria.
Company information adapted from PILOT’s company profile ↗ and Pilot Australia ↗.
PRODUCTS
Supplier-source catalogue previews. Prices, stock, orderable configurations and Australian compliance remain subject to confirmation.
Check electrical supply and capacity, installation space and access, environmental suitability, connections, approvals, commissioning and additional equipment before selecting a unit.
Every product model page contains Installation & Site Requirements for the selected configuration, with manufacturer manual and drawing links where supplied. Resolve all unconfirmed items before purchase or installation.
PEVC2108EHome-series AC charger. Catalogue-rated power options: 7.4 / 11 / 22 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
View catalogue details ↓
PEVC2107ECommercial-series AC charger. Catalogue-rated power options: 7.4 / 11 / 22 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
View catalogue details ↓
PEVC2201ECommercial-series AC charger. Catalogue-rated power options: 7.4 / 11 / 22 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
View catalogue details ↓
PEVC3401ECompact fast DC charger. Catalogue-rated power options: 30 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
View catalogue details ↓
PEVC3106EFreestanding fast DC charger. Catalogue-rated power options: 60 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
View catalogue details ↓
PEVC3107EUltra-fast DC charger. Catalogue-rated power options: 60 / 120 / 180 / 240 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
View catalogue details ↓
PEVC3108EUltra-fast DC charger. Catalogue-rated power options: 60 / 120 / 180 / 240 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
View catalogue details ↓
PEVC3302EDynamic split charging system. Catalogue-rated power options: 360 / 480 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
View catalogue details ↓Home-series AC charger. Catalogue-rated power options: 7.4 / 11 / 22 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
| Specification | Supplier-source value | Source |
|---|---|---|
| Input connection | Single-phase: 1P+N+PE or three-phase: 3P+N+PE | Catalogue V2.4; PDF page 11, printed page 8 |
| Input voltage | 230 Vac ±10% or 400 Vac ±10% | Catalogue V2.4; PDF page 11, printed page 8 |
| Input current | 16 A or 32 A | Catalogue V2.4; PDF page 11, printed page 8 |
| Frequency | 50 Hz or 60 Hz | Catalogue V2.4; PDF page 11, printed page 8 |
| Rated power | 7.4 / 11 / 22 kW | Catalogue V2.4; PDF page 11, printed page 8 |
| Output voltage | 230 Vac ±10% or 400 Vac ±10% | Catalogue V2.4; PDF page 11, printed page 8 |
| Output current | 16 A or 32 A | Catalogue V2.4; PDF page 11, printed page 8 |
| Connector options | IEC 62196-2 Type 2; SAE J1772 Type 1 optional | Catalogue V2.4; PDF page 11, printed page 8 |
| LCD display | — (not specified) | Catalogue V2.4; PDF page 11, printed page 8 |
| User authentication | RFID (ISO/IEC 14443) / app | Catalogue V2.4; PDF page 11, printed page 8 |
| LED indication | Green / blue / red | Catalogue V2.4; PDF page 11, printed page 8 |
| Energy metering | Embedded meter; catalogue states 1% accuracy | Catalogue V2.4; PDF page 11, printed page 8 |
| Backend connection | Bluetooth | Catalogue V2.4; PDF page 11, printed page 8 |
| Residual-current protection | Type A 30 mA + DC 6 mA | Catalogue V2.4; PDF page 11, printed page 8 |
| Electrical protection | Over/under voltage, overcurrent, short circuit, overtemperature and surge protection; see original model table for exact wording and additional listed protections. | Catalogue V2.4; PDF page 11, printed page 8 |
| Operating temperature | −30 to +50°C | Catalogue V2.4; PDF page 11, printed page 8 |
| Storage temperature | −40 to +85°C | Catalogue V2.4; PDF page 11, printed page 8 |
| Operating humidity | Maximum 93% RH, non-condensing | Catalogue V2.4; PDF page 11, printed page 8 |
| Operating altitude | ≤2000 m | Catalogue V2.4; PDF page 11, printed page 8 |
| IP / IK rating | IP65 / IK08 | Catalogue V2.4; PDF page 11, printed page 8 |
| Cooling | Natural cooling | Catalogue V2.4; PDF page 11, printed page 8 |
| Dimensions W × D × H | 208 × 102 × 358 mm | Catalogue V2.4; PDF page 11, printed page 8 |
| Weight | 3.3 kg net / 4 kg gross | Catalogue V2.4; PDF page 11, printed page 8 |
| Package dimensions W × D × H | 450 × 270 × 250 mm | Catalogue V2.4; PDF page 11, printed page 8 |
| Charging cable | 5 m; customisable (included configuration to be confirmed) | Catalogue V2.4; PDF page 11, printed page 8 |
| Mounting | Wall-mount / stand-mount | Catalogue V2.4; PDF page 11, printed page 8 |
| Listed marks | CE — source claims; exact certificates not provided here | Catalogue V2.4; PDF page 11, printed page 8 |
| Listed standards | EN 61851-1 2019; IEC 62955 2018; IEC 61008-1 2010; IEC/EN 62196-1 | Catalogue V2.4; PDF page 11, printed page 8 |
PILOT catalogue V2.4 — original pages 9–16 (model source page 11) ↗
Commercial-series AC charger. Catalogue-rated power options: 7.4 / 11 / 22 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
| Specification | Supplier-source value | Source |
|---|---|---|
| Input connection | Single-phase: 1P+N+PE or three-phase: 3P+N+PE | Catalogue V2.4; PDF page 13, printed page 10 |
| Input voltage | 230 Vac ±10% or 400 Vac ±10% | Catalogue V2.4; PDF page 13, printed page 10 |
| Input current | 16 A or 32 A | Catalogue V2.4; PDF page 13, printed page 10 |
| Frequency | 50 Hz or 60 Hz | Catalogue V2.4; PDF page 13, printed page 10 |
| Rated power | 7.4 / 11 / 22 kW | Catalogue V2.4; PDF page 13, printed page 10 |
| Output voltage | 230 Vac ±10% or 400 Vac ±10% | Catalogue V2.4; PDF page 13, printed page 10 |
| Output current | 16 A or 32 A | Catalogue V2.4; PDF page 13, printed page 10 |
| Connector options | IEC 62196-2 Type 2; SAE J1772 Type 1 optional | Catalogue V2.4; PDF page 13, printed page 10 |
| LCD display | 4.3-inch colour touchscreen (optional) | Catalogue V2.4; PDF page 13, printed page 10 |
| User authentication | RFID (ISO/IEC 14443) / app | Catalogue V2.4; PDF page 13, printed page 10 |
| LED indication | Green / blue / red | Catalogue V2.4; PDF page 13, printed page 10 |
| Energy metering | Embedded meter; catalogue states 1% accuracy | Catalogue V2.4; PDF page 13, printed page 10 |
| Backend connection | Bluetooth / Wi-Fi; 4G / Ethernet optional | Catalogue V2.4; PDF page 13, printed page 10 |
| Backend protocol | OCPP 1.6 J; OCPP 2.x described as “coming soon” | Catalogue V2.4; PDF page 13, printed page 10 |
| Residual-current protection | Type A 30 mA + DC 6 mA | Catalogue V2.4; PDF page 13, printed page 10 |
| Electrical protection | Over/under voltage, overcurrent, short circuit, overtemperature and surge protection; see original model table for exact wording and additional listed protections. | Catalogue V2.4; PDF page 13, printed page 10 |
| Operating temperature | −30 to +50°C | Catalogue V2.4; PDF page 13, printed page 10 |
| Storage temperature | −40 to +85°C | Catalogue V2.4; PDF page 13, printed page 10 |
| Operating humidity | Maximum 93% RH, non-condensing | Catalogue V2.4; PDF page 13, printed page 10 |
| Operating altitude | ≤2000 m | Catalogue V2.4; PDF page 13, printed page 10 |
| IP / IK rating | IP55 / IK08 | Catalogue V2.4; PDF page 13, printed page 10 |
| Cooling | Natural cooling | Catalogue V2.4; PDF page 13, printed page 10 |
| Dimensions W × D × H | 270 × 135 × 365 mm | Catalogue V2.4; PDF page 13, printed page 10 |
| Weight | 5.6 kg net / 7.2 kg gross | Catalogue V2.4; PDF page 13, printed page 10 |
| Package dimensions W × D × H | 500 × 330 × 265 mm | Catalogue V2.4; PDF page 13, printed page 10 |
| Charging cable | 5 m; customisable (included configuration to be confirmed) | Catalogue V2.4; PDF page 13, printed page 10 |
| Mounting | Wall-mount / stand-mount | Catalogue V2.4; PDF page 13, printed page 10 |
| Listed marks | TÜV / CE — source claims; exact certificates not provided here | Catalogue V2.4; PDF page 13, printed page 10 |
| Listed standards | EN 61851-1 2019; IEC 62955 2018; IEC 61008-1 2010; IEC/EN 62196-1 | Catalogue V2.4; PDF page 13, printed page 10 |
PILOT catalogue V2.4 — original pages 9–16 (model source page 13) ↗
Commercial-series AC charger. Catalogue-rated power options: 7.4 / 11 / 22 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
| Specification | Supplier-source value | Source |
|---|---|---|
| Input connection | Single-phase: 1P+N+PE or three-phase: 3P+N+PE | Catalogue V2.4; PDF page 15, printed page 12 |
| Input voltage | 230 Vac ±10% or 400 Vac ±10% | Catalogue V2.4; PDF page 15, printed page 12 |
| Input current | 16 A or 32 A | Catalogue V2.4; PDF page 15, printed page 12 |
| Frequency | 50 Hz or 60 Hz | Catalogue V2.4; PDF page 15, printed page 12 |
| Rated power | 7.4 / 11 / 22 kW | Catalogue V2.4; PDF page 15, printed page 12 |
| Output voltage | 230 Vac ±10% or 400 Vac ±10% | Catalogue V2.4; PDF page 15, printed page 12 |
| Output current | 16 A or 32 A | Catalogue V2.4; PDF page 15, printed page 12 |
| Connector options | IEC 62196-2 Type 2; SAE J1772 Type 1 optional | Catalogue V2.4; PDF page 15, printed page 12 |
| LCD display | 4.3-inch colour touchscreen (optional) | Catalogue V2.4; PDF page 15, printed page 12 |
| User authentication | RFID (ISO/IEC 14443) / app | Catalogue V2.4; PDF page 15, printed page 12 |
| LED indication | Green / blue / red | Catalogue V2.4; PDF page 15, printed page 12 |
| Energy metering | MID meter (catalogue claim) | Catalogue V2.4; PDF page 15, printed page 12 |
| Backend connection | Bluetooth / Wi-Fi / Ethernet; 4G optional | Catalogue V2.4; PDF page 15, printed page 12 |
| Backend protocol | OCPP 1.6 J; OCPP 2.x described as “coming soon” | Catalogue V2.4; PDF page 15, printed page 12 |
| Residual-current protection | Type A 30 mA + DC 6 mA | Catalogue V2.4; PDF page 15, printed page 12 |
| Electrical protection | Over/under voltage, overcurrent, short circuit, overtemperature and surge protection; see original model table for exact wording and additional listed protections. | Catalogue V2.4; PDF page 15, printed page 12 |
| Operating temperature | −30 to +50°C | Catalogue V2.4; PDF page 15, printed page 12 |
| Storage temperature | −40 to +85°C | Catalogue V2.4; PDF page 15, printed page 12 |
| Operating humidity | Maximum 93% RH, non-condensing | Catalogue V2.4; PDF page 15, printed page 12 |
| Operating altitude | ≤2000 m | Catalogue V2.4; PDF page 15, printed page 12 |
| IP / IK rating | IP55 / IK08 | Catalogue V2.4; PDF page 15, printed page 12 |
| Cooling | Natural cooling | Catalogue V2.4; PDF page 15, printed page 12 |
| Dimensions W × D × H | 300 × 154 × 420 mm | Catalogue V2.4; PDF page 15, printed page 12 |
| Weight | 5.9 kg net / 7.7 kg gross | Catalogue V2.4; PDF page 15, printed page 12 |
| Package dimensions W × D × H | 490 × 390 × 280 mm | Catalogue V2.4; PDF page 15, printed page 12 |
| Charging cable | 5 m; customisable (included configuration to be confirmed) | Catalogue V2.4; PDF page 15, printed page 12 |
| Mounting | Wall-mount / stand-mount | Catalogue V2.4; PDF page 15, printed page 12 |
| Listed marks | TÜV / CE / OCPP — source claims; exact certificates not provided here | Catalogue V2.4; PDF page 15, printed page 12 |
| Listed standards | EN 61851-1 2019; IEC 62955 2018; IEC 61008-1 2010; IEC/EN 62196-1 | Catalogue V2.4; PDF page 15, printed page 12 |
PILOT catalogue V2.4 — original pages 9–16 (model source page 15) ↗
Compact fast DC charger. Catalogue-rated power options: 30 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
| Specification | Supplier-source value | Source |
|---|---|---|
| Input connection | Three-phase: 3P+N+PE | Catalogue V2.4; PDF page 17, printed page 14 |
| Input voltage | 400 Vac ±10% | Catalogue V2.4; PDF page 17, printed page 14 |
| Frequency | 50 Hz or 60 Hz | Catalogue V2.4; PDF page 17, printed page 14 |
| Rated power | 30 kW | Catalogue V2.4; PDF page 17, printed page 14 |
| Output voltage | 150–1000 V DC | Catalogue V2.4; PDF page 17, printed page 14 |
| Output current | 100 A | Catalogue V2.4; PDF page 17, printed page 14 |
| THDi | ≤5% | Catalogue V2.4; PDF page 17, printed page 14 |
| Power factor | ≥0.98 | Catalogue V2.4; PDF page 17, printed page 14 |
| Connector options | CCS2; CCS1 / CHAdeMO optional | Catalogue V2.4; PDF page 17, printed page 14 |
| LCD display | 4.3-inch colour touchscreen | Catalogue V2.4; PDF page 17, printed page 14 |
| User authentication | RFID (ISO/IEC 14443); app / credit-card customisation | Catalogue V2.4; PDF page 17, printed page 14 |
| LED indication | Green / blue / red | Catalogue V2.4; PDF page 17, printed page 14 |
| Energy metering | DC meter; catalogue states 1% accuracy | Catalogue V2.4; PDF page 17, printed page 14 |
| Backend connection | Ethernet / Bluetooth / Wi-Fi; 4G optional | Catalogue V2.4; PDF page 17, printed page 14 |
| Charging protocols | ISO 15118 / DIN 70121 | Catalogue V2.4; PDF page 17, printed page 14 |
| Backend protocol | OCPP 1.6 J; OCPP 2.x described as “coming soon” | Catalogue V2.4; PDF page 17, printed page 14 |
| Residual-current protection | Residual-current device: yes (catalogue wording) | Catalogue V2.4; PDF page 17, printed page 14 |
| Internal fuse | Yes | Catalogue V2.4; PDF page 17, printed page 14 |
| Electrical protection | Over/under voltage, overcurrent, short circuit, overtemperature and surge protection; see original model table for exact wording and additional listed protections. | Catalogue V2.4; PDF page 17, printed page 14 |
| Operating temperature | −30 to +50°C | Catalogue V2.4; PDF page 17, printed page 14 |
| Storage temperature | −40 to +75°C | Catalogue V2.4; PDF page 17, printed page 14 |
| Operating humidity | Maximum 93% RH, non-condensing | Catalogue V2.4; PDF page 17, printed page 14 |
| Operating altitude | ≤2000 m | Catalogue V2.4; PDF page 17, printed page 14 |
| IP / IK rating | IP54 / IK10 | Catalogue V2.4; PDF page 17, printed page 14 |
| Cooling | Fan cooling | Catalogue V2.4; PDF page 17, printed page 14 |
| Dimensions W × D × H | 650 × 160 × 550 mm | Catalogue V2.4; PDF page 17, printed page 14 |
| Weight | 80 kg net / 85.7 kg gross | Catalogue V2.4; PDF page 17, printed page 14 |
| Package dimensions W × D × H | 808 × 438 × 748 mm | Catalogue V2.4; PDF page 17, printed page 14 |
| Charging cable | 5 m; customisable (included configuration to be confirmed) | Catalogue V2.4; PDF page 17, printed page 14 |
| Mounting | Wall-mount / stand-mount | Catalogue V2.4; PDF page 17, printed page 14 |
| Listed marks | CE — source claims; exact certificates not provided here | Catalogue V2.4; PDF page 17, printed page 14 |
| Listed standards | IEC 62196-1 / IEC 62196-3 / IEC 61851-1 / IEC 61851-23 / IEC 61851-24 | Catalogue V2.4; PDF page 17, printed page 14 |
PILOT catalogue V2.4 — original pages 17–24 (model source page 17) ↗
Freestanding fast DC charger. Catalogue-rated power options: 60 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
| Specification | Supplier-source value | Source |
|---|---|---|
| Input connection | Three-phase: 3P+N+PE | Catalogue V2.4; PDF page 19, printed page 16 |
| Input voltage | 400 Vac ±10% | Catalogue V2.4; PDF page 19, printed page 16 |
| Frequency | 50 Hz or 60 Hz | Catalogue V2.4; PDF page 19, printed page 16 |
| Rated power | 60 kW | Catalogue V2.4; PDF page 19, printed page 16 |
| Output voltage | 150–1000 V DC | Catalogue V2.4; PDF page 19, printed page 16 |
| Output current | 200 A | Catalogue V2.4; PDF page 19, printed page 16 |
| THDi | ≤5% | Catalogue V2.4; PDF page 19, printed page 16 |
| Power factor | ≥0.98 | Catalogue V2.4; PDF page 19, printed page 16 |
| Connector options | CCS2; CCS1 / CHAdeMO optional | Catalogue V2.4; PDF page 19, printed page 16 |
| LCD display | 7-inch colour touchscreen; 12-inch customisation | Catalogue V2.4; PDF page 19, printed page 16 |
| User authentication | RFID (ISO/IEC 14443); app / credit-card customisation | Catalogue V2.4; PDF page 19, printed page 16 |
| LED indication | Green / blue / red | Catalogue V2.4; PDF page 19, printed page 16 |
| Charging interfaces | 1 or 2 | Catalogue V2.4; PDF page 19, printed page 16 |
| Energy metering | DC meter; catalogue states 1% accuracy | Catalogue V2.4; PDF page 19, printed page 16 |
| Backend connection | Ethernet; 4G optional | Catalogue V2.4; PDF page 19, printed page 16 |
| Charging protocols | ISO 15118 / DIN 70121 | Catalogue V2.4; PDF page 19, printed page 16 |
| Backend protocol | OCPP 1.6 J; OCPP 2.x described as “coming soon” | Catalogue V2.4; PDF page 19, printed page 16 |
| Residual-current protection | Residual-current device: yes (catalogue wording) | Catalogue V2.4; PDF page 19, printed page 16 |
| Internal fuse | Yes | Catalogue V2.4; PDF page 19, printed page 16 |
| Electrical protection | Over/under voltage, overcurrent, short circuit, overtemperature and surge protection; see original model table for exact wording and additional listed protections. | Catalogue V2.4; PDF page 19, printed page 16 |
| Operating temperature | −30 to +50°C | Catalogue V2.4; PDF page 19, printed page 16 |
| Storage temperature | −40 to +75°C | Catalogue V2.4; PDF page 19, printed page 16 |
| Operating humidity | Maximum 93% RH, non-condensing | Catalogue V2.4; PDF page 19, printed page 16 |
| Operating altitude | ≤2000 m | Catalogue V2.4; PDF page 19, printed page 16 |
| IP / IK rating | IP54 / IK10 | Catalogue V2.4; PDF page 19, printed page 16 |
| Cooling | Fan cooling | Catalogue V2.4; PDF page 19, printed page 16 |
| Dimensions W × D × H | 700 × 240 × 1750 mm | Catalogue V2.4; PDF page 19, printed page 16 |
| Weight | 220 kg net / 230 kg gross | Catalogue V2.4; PDF page 19, printed page 16 |
| Package dimensions W × D × H | 1100 × 750 × 1890 mm | Catalogue V2.4; PDF page 19, printed page 16 |
| Charging cable | 5 m; customisable (included configuration to be confirmed) | Catalogue V2.4; PDF page 19, printed page 16 |
| Mounting | Freestanding | Catalogue V2.4; PDF page 19, printed page 16 |
| Listed marks | CE — source claims; exact certificates not provided here | Catalogue V2.4; PDF page 19, printed page 16 |
| Listed standards | IEC 62196-1 / IEC 62196-3 / IEC 61851-1 / IEC 61851-23 / IEC 61851-24 | Catalogue V2.4; PDF page 19, printed page 16 |
PILOT catalogue V2.4 — original pages 17–24 (model source page 19) ↗
Ultra-fast DC charger. Catalogue-rated power options: 60 / 120 / 180 / 240 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
| Specification | Supplier-source value | Source |
|---|---|---|
| Input connection | Three-phase: 3P+N+PE | Catalogue V2.4; PDF page 21, printed page 18 |
| Input voltage | 400 Vac ±10% | Catalogue V2.4; PDF page 21, printed page 18 |
| Frequency | 50 Hz or 60 Hz | Catalogue V2.4; PDF page 21, printed page 18 |
| Rated power | 60 / 120 / 180 / 240 kW | Catalogue V2.4; PDF page 21, printed page 18 |
| Output voltage | 150–1000 V DC | Catalogue V2.4; PDF page 21, printed page 18 |
| Output current | 250 A (table; graph discrepancy retained below) | Catalogue V2.4; PDF page 21, printed page 18 |
| THDi | ≤5% | Catalogue V2.4; PDF page 21, printed page 18 |
| Power factor | ≥0.98 | Catalogue V2.4; PDF page 21, printed page 18 |
| Connector options | CCS2; CCS1 / CHAdeMO optional | Catalogue V2.4; PDF page 21, printed page 18 |
| LCD display | 7-inch colour touchscreen; 12-inch customisation | Catalogue V2.4; PDF page 21, printed page 18 |
| User authentication | RFID (ISO/IEC 14443); app / credit-card customisation | Catalogue V2.4; PDF page 21, printed page 18 |
| LED indication | Green / blue / red | Catalogue V2.4; PDF page 21, printed page 18 |
| Charging interfaces | 1 or 2 | Catalogue V2.4; PDF page 21, printed page 18 |
| Energy metering | DC meter; catalogue states 1% accuracy | Catalogue V2.4; PDF page 21, printed page 18 |
| Backend connection | Ethernet; 4G optional | Catalogue V2.4; PDF page 21, printed page 18 |
| Charging protocols | ISO 15118 / DIN 70121 | Catalogue V2.4; PDF page 21, printed page 18 |
| Backend protocol | OCPP 1.6 J; OCPP 2.x described as “coming soon” | Catalogue V2.4; PDF page 21, printed page 18 |
| Residual-current protection | Residual-current device: yes (catalogue wording) | Catalogue V2.4; PDF page 21, printed page 18 |
| Internal fuse | Yes | Catalogue V2.4; PDF page 21, printed page 18 |
| Electrical protection | Over/under voltage, overcurrent, short circuit, overtemperature and surge protection; see original model table for exact wording and additional listed protections. | Catalogue V2.4; PDF page 21, printed page 18 |
| Operating temperature | −30 to +50°C | Catalogue V2.4; PDF page 21, printed page 18 |
| Storage temperature | −40 to +75°C | Catalogue V2.4; PDF page 21, printed page 18 |
| Operating humidity | Maximum 93% RH, non-condensing | Catalogue V2.4; PDF page 21, printed page 18 |
| Operating altitude | ≤2000 m | Catalogue V2.4; PDF page 21, printed page 18 |
| IP / IK rating | IP54 / IK10 | Catalogue V2.4; PDF page 21, printed page 18 |
| Cooling | Fan cooling | Catalogue V2.4; PDF page 21, printed page 18 |
| Dimensions W × D × H | 700 × 550 × 1800 mm | Catalogue V2.4; PDF page 21, printed page 18 |
| Weight | 363 kg net / 380 kg gross | Catalogue V2.4; PDF page 21, printed page 18 |
| Package dimensions W × D × H | 950 × 720 × 1950 mm | Catalogue V2.4; PDF page 21, printed page 18 |
| Charging cable | 5 m; customisable (included configuration to be confirmed) | Catalogue V2.4; PDF page 21, printed page 18 |
| Mounting | Freestanding | Catalogue V2.4; PDF page 21, printed page 18 |
| Listed marks | CE — source claims; exact certificates not provided here | Catalogue V2.4; PDF page 21, printed page 18 |
| Listed standards | IEC 62196-1 / IEC 62196-3 / IEC 61851-1 / IEC 61851-23 / IEC 61851-24 | Catalogue V2.4; PDF page 21, printed page 18 |
PILOT catalogue V2.4 — original pages 17–24 (model source page 21) ↗
Ultra-fast DC charger. Catalogue-rated power options: 60 / 120 / 180 / 240 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
| Specification | Supplier-source value | Source |
|---|---|---|
| Input connection | Three-phase: 3P+N+PE | Catalogue V2.4; PDF page 23, printed page 20 |
| Input voltage | 400 Vac ±10% | Catalogue V2.4; PDF page 23, printed page 20 |
| Frequency | 50 Hz or 60 Hz | Catalogue V2.4; PDF page 23, printed page 20 |
| Rated power | 60 / 120 / 180 / 240 kW | Catalogue V2.4; PDF page 23, printed page 20 |
| Output voltage | 150–1000 V DC | Catalogue V2.4; PDF page 23, printed page 20 |
| Output current | 200 A; 250 A optional | Catalogue V2.4; PDF page 23, printed page 20 |
| THDi | ≤5% | Catalogue V2.4; PDF page 23, printed page 20 |
| Power factor | ≥0.98 | Catalogue V2.4; PDF page 23, printed page 20 |
| Connector options | CCS2; CCS1 / CHAdeMO optional | Catalogue V2.4; PDF page 23, printed page 20 |
| LCD display | 7-inch colour touchscreen; 12-inch customisation | Catalogue V2.4; PDF page 23, printed page 20 |
| User authentication | RFID (ISO/IEC 14443); app / credit-card customisation | Catalogue V2.4; PDF page 23, printed page 20 |
| LED indication | Green / blue / red | Catalogue V2.4; PDF page 23, printed page 20 |
| Charging interfaces | 1 or 2 | Catalogue V2.4; PDF page 23, printed page 20 |
| Energy metering | DC meter; catalogue states 1% accuracy | Catalogue V2.4; PDF page 23, printed page 20 |
| Backend connection | Ethernet; 4G optional | Catalogue V2.4; PDF page 23, printed page 20 |
| Charging protocols | ISO 15118 / DIN 70121 | Catalogue V2.4; PDF page 23, printed page 20 |
| Backend protocol | OCPP 1.6 J; OCPP 2.x described as “coming soon” | Catalogue V2.4; PDF page 23, printed page 20 |
| Residual-current protection | Residual-current device: yes (catalogue wording) | Catalogue V2.4; PDF page 23, printed page 20 |
| Internal fuse | Yes | Catalogue V2.4; PDF page 23, printed page 20 |
| Electrical protection | Over/under voltage, overcurrent, short circuit, overtemperature and surge protection; see original model table for exact wording and additional listed protections. | Catalogue V2.4; PDF page 23, printed page 20 |
| Operating temperature | −30 to +50°C | Catalogue V2.4; PDF page 23, printed page 20 |
| Storage temperature | −40 to +75°C | Catalogue V2.4; PDF page 23, printed page 20 |
| Operating humidity | Maximum 93% RH, non-condensing | Catalogue V2.4; PDF page 23, printed page 20 |
| Operating altitude | ≤2000 m | Catalogue V2.4; PDF page 23, printed page 20 |
| IP / IK rating | IP54 / IK10 | Catalogue V2.4; PDF page 23, printed page 20 |
| Cooling | Fan cooling | Catalogue V2.4; PDF page 23, printed page 20 |
| Dimensions W × D × H | 750 × 750 × 1900 mm | Catalogue V2.4; PDF page 23, printed page 20 |
| Weight | 411 kg net / 428 kg gross | Catalogue V2.4; PDF page 23, printed page 20 |
| Package dimensions W × D × H | 1000 × 920 × 2050 mm | Catalogue V2.4; PDF page 23, printed page 20 |
| Charging cable | 5 m; customisable (included configuration to be confirmed) | Catalogue V2.4; PDF page 23, printed page 20 |
| Mounting | Freestanding | Catalogue V2.4; PDF page 23, printed page 20 |
| Listed marks | TÜV / CE / CB / OCPP — source claims; exact certificates not provided here | Catalogue V2.4; PDF page 23, printed page 20 |
| Listed standards | IEC 62196-1 / IEC 62196-3 / IEC 61851-1 / IEC 61851-23 / IEC 61851-24 | Catalogue V2.4; PDF page 23, printed page 20 |
PILOT catalogue V2.4 — original pages 17–24 (model source page 23) ↗
Dynamic split charging system. Catalogue-rated power options: 360 / 480 kW. Exact orderable Australian configuration and included equipment require supplier confirmation.
| Specification | Supplier-source value | Source |
|---|---|---|
| Input connection | Three-phase: 3P+N+PE | Catalogue V2.4; PDF page 25, printed page 22 |
| Input voltage | 400 Vac ±10% | Catalogue V2.4; PDF page 25, printed page 22 |
| Frequency | 50 Hz or 60 Hz | Catalogue V2.4; PDF page 25, printed page 22 |
| Rated power | 360 / 480 kW | Catalogue V2.4; PDF page 25, printed page 22 |
| Output voltage | 150–1000 V DC | Catalogue V2.4; PDF page 25, printed page 22 |
| Output current | 250 A; 500 A optional | Catalogue V2.4; PDF page 25, printed page 22 |
| THDi | ≤5% | Catalogue V2.4; PDF page 25, printed page 22 |
| Power factor | ≥0.99 at 50–100% load | Catalogue V2.4; PDF page 25, printed page 22 |
| Connector options | CCS2; CCS1 optional | Catalogue V2.4; PDF page 25, printed page 22 |
| LCD display | 7-inch colour touchscreen | Catalogue V2.4; PDF page 25, printed page 22 |
| User authentication | RFID (ISO/IEC 14443); app / credit-card customisation | Catalogue V2.4; PDF page 25, printed page 22 |
| Output ports | 8 maximum (system configuration to be confirmed) | Catalogue V2.4; PDF page 25, printed page 22 |
| Energy metering | Not stated in technical table | Catalogue V2.4; PDF page 25, printed page 22 |
| Backend connection | Ethernet; 4G optional | Catalogue V2.4; PDF page 25, printed page 22 |
| Charging protocols | ISO 15118 / DIN 70121 | Catalogue V2.4; PDF page 25, printed page 22 |
| Backend protocol | OCPP 1.6 J; OCPP 2.x described as “coming soon” | Catalogue V2.4; PDF page 25, printed page 22 |
| Residual-current protection | Residual-current device: yes (catalogue wording) | Catalogue V2.4; PDF page 25, printed page 22 |
| Electrical protection | Over/under voltage, overcurrent, short circuit, overtemperature and surge protection; see original model table for exact wording and additional listed protections. | Catalogue V2.4; PDF page 25, printed page 22 |
| Operating temperature | −20 to +50°C | Catalogue V2.4; PDF page 25, printed page 22 |
| Storage temperature | −40 to +75°C | Catalogue V2.4; PDF page 25, printed page 22 |
| Operating humidity | 5–95% RH, non-condensing | Catalogue V2.4; PDF page 25, printed page 22 |
| Operating altitude | ≤2000 m | Catalogue V2.4; PDF page 25, printed page 22 |
| IP / IK rating | IP55 / IK10 | Catalogue V2.4; PDF page 25, printed page 22 |
| Cooling | Forced-air cooling | Catalogue V2.4; PDF page 25, printed page 22 |
| Dimensions W × D × H | 850 × 1600 × 2000 mm | Catalogue V2.4; PDF page 25, printed page 22 |
| Weight | 700 kg (net/gross basis not stated) | Catalogue V2.4; PDF page 25, printed page 22 |
| Package dimensions W × D × H | Not stated; separate cabinet/dispenser packing confirmation required | Catalogue V2.4; PDF page 25, printed page 22 |
| Charging cable | 5 m; customisable (included configuration to be confirmed) | Catalogue V2.4; PDF page 25, printed page 22 |
| Mounting | Freestanding | Catalogue V2.4; PDF page 25, printed page 22 |
| Listed marks | CE — source claims; exact certificates not provided here | Catalogue V2.4; PDF page 25, printed page 22 |
| Listed standards | IEC 62196-1 / IEC 62196-3 / IEC 61851-1 / IEC 61851-23 / IEC 61851-24 | Catalogue V2.4; PDF page 25, printed page 22 |
PILOT catalogue V2.4 — original pages 25–32 (model source page 25) ↗
SOLUTIONS / AUSTRALIA
Explore PILOT’s technology areas through the needs of an Australian project. Choose a pathway below, then discuss the scope with the local team.
Manufacturer solution illustration01 / Homes · Workplaces · Retail · Fleets
Plan charging around the time vehicles spend on site. Explore AC catalogue families for home and destination settings, or DC families for commercial and fleet discussions.
Number of vehicles, dwell time, available supply, connector requirements and charging management.
Manufacturer solution illustration02 / Commercial premises · Industry · Solar sites
PILOT’s battery energy storage solutions offer a starting point for discussions about storing solar generation, managing peak demand and planning backup capability. A site study determines the appropriate system and controls.
Load profile, solar generation, tariff structure, critical loads and connection requirements.
Manufacturer solution illustration03 / Business sites · Charging hubs · Property developments
Consider how rooftop or on-site solar, battery storage and EV charging could work together. Coordinate the energy flows and operating priorities rather than selecting each element in isolation.
Site energy balance, charger demand, storage sizing, controls and network approval.
Manufacturer solution illustration04 / Buildings · Facilities · Commercial portfolios
Energy meters and monitoring provide a clearer picture of where electricity is used. Explore measurement and management options for facilities, equipment and multi-site energy reviews.
Measurement points, accuracy requirements, communications, existing systems and reporting needs.
Manufacturer solution illustration05 / Regional sites · Campuses · Remote operations
A microgrid approach coordinates local generation, storage and demand. For Australian sites considering resilience or greater control, begin with an engineering assessment of the operating conditions and connection arrangements.
Grid-connected or off-grid operation, reliability needs, generation mix and control strategy.
For data-centre projects, discuss electrical monitoring, distribution visibility and integration requirements with the technical team.
Explore PILOT’s data-centre solutions ↗These are project planning pathways, not approved engineering designs or confirmed Australian product availability. EV charger catalogue records are available in this RRE store; other technology areas are enquiries. Exact equipment, compliance, network connection, installation and support must be confirmed for each project.
Adapted for Australian enquiries from PILOT’s manufacturer solutions ↗. Illustrations show concepts, not completed Australian projects.
CASE STUDIES / PROJECT EXPERIENCE
Discover projects published by PILOT and Pilot Australia. Australian examples lead the collection, followed by international applications for comparison.
Locations, equipment and photographs are attributed to the linked company sources. These are not RRE-delivered projects or independent performance assessments.

Integrated energy
PILOT describes an Australian demonstration combining solar generation, storage and EV charging. The published case explains how battery cabinets were added to address limited transformer capacity.
| Location | Melbourne, Australia |
|---|---|
| Reported equipment | 120 kW dual-cable DC charger · two 50 kW / 125 kWh storage cabinets |
| Planning perspective | A useful discussion point for sites assessing charging demand against an existing electrical connection. |

Commercial EV charging
Pilot Australia reports a dealership installation using a wall-mounted DC charger to prepare newly arrived electric vehicles for customer delivery.
| Location | Victoria, Australia |
|---|---|
| Reported equipment | PEVC3401E · 30 kW |
| Planning perspective | Explore charging around vehicle preparation, workshop space and delivery schedules. |

Destination charging
Pilot Australia presents a Victorian commercial AC charging example using the PEVC2107E family.
| Location | Victoria, Australia |
|---|---|
| Reported equipment | PEVC2107E · 22 kW as reported by Pilot Australia |
| Planning perspective | Consider longer vehicle dwell times at workplaces and other business destinations. |

Commercial EV charging
PILOT’s E-Boost case describes compact DC charging at BYD-authorised service centres in Poland, with wall-mounted and stand-mounted arrangements.
| Location | Poland |
|---|---|
| Reported equipment | PEVC3401E · 30 kW |
| Planning perspective | Compare installation space and access requirements when planning a dealership or workshop site. |

Off-grid energy
PILOT reports a remote hospitality project combining solar, battery storage and diesel generation where municipal grid supply was unavailable.
| Location | Xinjiang, China |
|---|---|
| Reported equipment | PL-EL · 400 kW / 836 kWh BESS |
| Planning perspective | A reference for discussing remote-site energy coordination. Australian conditions require their own engineering assessment. |
Bring a relevant reference to your discussion with the Australian team. Confirm the configuration, approvals and commercial arrangements for your own project.
SERVICES / AUSTRALIAN ENQUIRIES
Connect with Pilot Technology Australia for pre-sales discussions, technical enquiries and after-sales arrangements across charging, energy metering and storage.

LOCAL CONTACT / GLOBAL TECHNOLOGY
Use the Australian contact for your project enquiry. Share your intended application and exact product family so the team can identify the information and support you need.
0474 207 900| Service area | Discuss with PILOT | Bring to your enquiry |
|---|---|---|
| Product selection & pre-sales | Compare catalogue families with the intended application and identify the configuration requiring a proposal. | Application, preferred models, quantity and required timing. |
| Technical & system enquiries | Discuss charging, metering, storage, communications and integration requirements with the technical team. | Site postcode, electrical supply, vehicle or load profile and existing equipment. |
| Australian supply & logistics | Ask about local availability, lead times, delivery scope and supplied accessories. | Exact model, delivery postcode, access conditions and required quantities. |
| Installation & commissioning coordination | Establish what documentation and supplier assistance are available to your project team and licensed installer. | Site drawings, network requirements and installer questions. |
| After-sales, warranty & spare parts | Confirm written coverage, service contacts, parts, labour and freight responsibilities for the selected equipment. | Model, serial number, purchase details and a description of the issue. |
| OEM / ODM / SKD enquiries | PILOT invites manufacturing and customisation discussions. Scope, feasibility and commercial terms require a separate proposal. | Brand requirements, specifications, volume and documentation needs. |
Service availability, stock, response times and on-site coverage must be confirmed with PILOT. This page does not promise installation, a warranty entitlement or a service-level agreement. Purchasing and live bookings through RRE remain on HOLD.
Pilot Technology Australia Pty Ltd · Mulgrave, Victoria. Australian business enquiries are separate from storefront administration.
Service areas reflect Pilot Australia’s published offering ↗ and PILOT’s manufacturing enquiry options ↗.
Confirm the supplier’s installation coverage, nominated licensed installers, site assessment, commissioning, technical support, servicing and warranty responsibilities.
Supplier-specific installation and support arrangements have not been supplied and remain unconfirmed.
Every product model page contains Installation & Site Requirements for the selected configuration, with manufacturer manual and drawing links where supplied. Resolve all unconfirmed items before purchase or installation.
INFO CENTER / DOCUMENTS & KNOWLEDGE
Keep the original charging catalogue, practical reading and official company updates together. Start with the model you are considering, then follow the supporting information.
01 / SOURCE DOCUMENTS
The original supplied catalogue is retained in four PDF parts. Page references in RRE specification tables point back to these documents.
Zhuhai Sino Energy Technology Co., Ltd. is also named in the supplied catalogue; the company/brand relationship remains subject to confirmation.
Browse the eight RRE charger families →02 / TECHNICAL READING

Consider site supply capacity, operating requirements and the business case before selecting equipment.
Read the official guide ↗
Explore charging schedules and the questions to ask about electricity tariffs, daily use and available solar.
Read the official guide ↗
Read about AC-coupled storage and the integration questions that arise when adding batteries to a solar system.
Read the official guide ↗Manufacturer articles provide general background. Tariffs, regulations, standards and installation requirements vary by location; confirm Australian applicability with your project professionals.
03 / AUSTRALIAN PROJECT CHECKLIST
| Topic | Information to request |
|---|---|
| Exact equipment | Orderable model, connector, supply, firmware and included accessories. |
| Australian requirements | Model-specific certification and evidence relevant to the intended installation. |
| System integration | Vehicle, backend, communications and energy-management compatibility. |
| Commercial scope | AUD pricing, quantities, packing, availability and delivery responsibilities. |
| Long-term support | Written warranty terms, service coverage, manuals and spare parts arrangements. |
04 / COMPANY UPDATES & MEDIA
VIDEOS
Explore Pilot’s energy animation and the Facebook videos selected for this storefront.
Discover more company and product updates on Facebook.
The manufacturer presentation featured on this store’s landing page.
Facebook videoWatch this video on Facebook.
Facebook ReelWatch this video on Facebook.
Facebook ReelWatch this video on Facebook.
Facebook ReelWatch this video on Facebook.
Facebook ReelWatch this video on Facebook.
Facebook ReelWatch this video on Facebook.
Facebook ReelWatch this video on Facebook.
Facebook ReelWatch this video on Facebook.
Facebook ReelWatch this video on Facebook.
Facebook ReelWatch this video on Facebook.
Facebook ReelWatch this video on Facebook.
Facebook videos open on Facebook, where sign-in or regional viewing restrictions may apply. Video labels summarise the topics in the company’s Facebook posts.

CONTACT US / AUSTRALIA
Discuss digital energy and EV charging solutions for your business. Connect with the Australian team to match your project requirements with the right product information.

These are public Australian business contact details.
MAKE YOUR ENQUIRY COUNT
| Your application | Home, business, fleet, retail, industrial or another project setting. |
|---|---|
| Your site | Postcode, available electrical supply and proposed installation. |
| Your equipment | Product family, configuration, quantity and intended use. |
| Your questions | Australian compliance, delivery, installation, warranty and support. |
Australian contact details supplied by the company and listed on PILOT’s official contact page ↗.